Catchment Area | 68 Km 2 |
---|---|
Design Discharge | 1.95 m 3 /s |
Average Annual Discharge | 3.10 m 3 /s |
Maximum Gross Head | 156.5 m |
Penstock- Length | 200.0 m (Excluding length after bifurcation) |
---|---|
Penstock-Diameter | 1.00 m |
Tailrace Canal Length | 24 m |
Type | Horizontal Axis Pelton |
---|---|
Number of Units | 2 |
Rated Output | 1,380 kW |
Type | Electro-hydraulic with PID |
---|